/dev/sda
=== START OF INFORMATION SECTION ===
Model Family: Toshiba P300
Device Model: TOSHIBA HDWD110
Serial Number: --
LU WWN Device Id: 5 000039 ...
Firmware Version: MS2OA8J0
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Mar 25 17:47:38 2024 +06
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 7216) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 121) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
2 Throughput_Performance P-S--- 142 142 054 - 71
3 Spin_Up_Time POS--- 127 127 024 - 180 (Average 180)
4 Start_Stop_Count -O--C- 100 100 000 - 1132
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
8 Seek_Time_Performance P-S--- 115 115 020 - 34
9 Power_On_Hours -O--C- 100 100 000 - 1231
10 Spin_Retry_Count PO--C- 100 100 060 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 1109
192 Power-Off_Retract_Count -O--CK 100 100 000 - 1133
193 Load_Cycle_Count -O--C- 100 100 000 - 1133
194 Temperature_Celsius -O---- 146 146 000 - 41 (Min/Max 17/45)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O---K 100 100 000 - 0
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL R/O 7 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x20 GPL R/O 1 Streaming performance log [OBS-8]
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
SCT Support Level: 1
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 41 Celsius
Power Cycle Min/Max Temperature: 30/42 Celsius
Lifetime Min/Max Temperature: 17/45 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/70 Celsius
Temperature History Size (Index): 128 (2)
Index Estimated Time Temperature Celsius
3 2024-03-25 15:40 40 *********************
... ..( 3 skipped). .. *********************
7 2024-03-25 15:44 40 *********************
8 2024-03-25 15:45 41 **********************
9 2024-03-25 15:46 40 *********************
10 2024-03-25 15:47 40 *********************
11 2024-03-25 15:48 41 **********************
... ..( 4 skipped). .. **********************
16 2024-03-25 15:53 41 **********************
17 2024-03-25 15:54 42 ***********************
18 2024-03-25 15:55 42 ***********************
19 2024-03-25 15:56 41 **********************
20 2024-03-25 15:57 41 **********************
21 2024-03-25 15:58 41 **********************
22 2024-03-25 15:59 42 ***********************
23 2024-03-25 16:00 41 **********************
... ..( 6 skipped). .. **********************
30 2024-03-25 16:07 41 **********************
31 2024-03-25 16:08 ? -
32 2024-03-25 16:09 31 ************
33 2024-03-25 16:10 32 *************
34 2024-03-25 16:11 32 *************
35 2024-03-25 16:12 32 *************
36 2024-03-25 16:13 33 **************
37 2024-03-25 16:14 33 **************
38 2024-03-25 16:15 34 ***************
39 2024-03-25 16:16 34 ***************
40 2024-03-25 16:17 35 ****************
... ..( 2 skipped). .. ****************
43 2024-03-25 16:20 35 ****************
44 2024-03-25 16:21 36 *****************
... ..( 3 skipped). .. *****************
48 2024-03-25 16:25 36 *****************
49 2024-03-25 16:26 37 ******************
... ..( 4 skipped). .. ******************
54 2024-03-25 16:31 37 ******************
55 2024-03-25 16:32 38 *******************
... ..( 8 skipped). .. *******************
64 2024-03-25 16:41 38 *******************
65 2024-03-25 16:42 39 ********************
... ..( 14 skipped). .. ********************
80 2024-03-25 16:57 39 ********************
81 2024-03-25 16:58 40 *********************
... ..( 33 skipped). .. *********************
115 2024-03-25 17:32 40 *********************
116 2024-03-25 17:33 41 **********************
117 2024-03-25 17:34 40 *********************
... ..( 3 skipped). .. *********************
121 2024-03-25 17:38 40 *********************
122 2024-03-25 17:39 41 **********************
... ..( 6 skipped). .. **********************
1 2024-03-25 17:46 41 **********************
2 2024-03-25 17:47 42 ***********************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 1109 --- Lifetime Power-On Resets
0x01 0x010 4 1231 --- Power-on Hours
0x01 0x018 6 8698521479 --- Logical Sectors Written
0x01 0x020 6 85145327 --- Number of Write Commands
0x01 0x028 6 19334403209 --- Logical Sectors Read
0x01 0x030 6 172774640 --- Number of Read Commands
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
0x03 0x008 4 1229 --- Spindle Motor Power-on Hours
0x03 0x010 4 1229 --- Head Flying Hours
0x03 0x018 4 1133 --- Head Load Events
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
0x03 0x028 4 33 --- Read Recovery Attempts
0x03 0x030 4 2 --- Number of Mechanical Start Failures
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 41 --- Current Temperature
0x05 0x010 1 36 N-- Average Short Term Temperature
0x05 0x018 1 36 N-- Average Long Term Temperature
0x05 0x020 1 45 --- Highest Temperature
0x05 0x028 1 17 --- Lowest Temperature
0x05 0x030 1 37 N-- Highest Average Short Term Temperature
0x05 0x038 1 25 N-- Lowest Average Short Term Temperature
0x05 0x040 1 36 N-- Highest Average Long Term Temperature
0x05 0x048 1 25 N-- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 4883 --- Number of Hardware Resets
0x06 0x010 4 3749 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
/dev/sdb
=== START OF INFORMATION SECTION ===
Model Family: Seagate Samsung SpinPoint M8 (AF)
Device Model: ST1000LM024 HN-M101MBB
Serial Number: --
LU WWN Device Id: 5 0004cf ...
Firmware Version: 2AR20002
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Mon Mar 25 17:47:40 2024 +06
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (13140) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 219) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 051 - 156427
2 Throughput_Performance -OS--K 252 252 000 - 0
3 Spin_Up_Time PO---K 090 080 025 - 3055
4 Start_Stop_Count -O--CK 096 096 000 - 4694
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
7 Seek_Error_Rate -OSR-K 252 252 051 - 0
8 Seek_Time_Performance --S--K 252 252 015 - 0
9 Power_On_Hours -O--CK 100 100 000 - 19771
10 Spin_Retry_Count -O--CK 252 252 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 259
12 Power_Cycle_Count -O--CK 096 096 000 - 4064
191 G-Sense_Error_Rate -O---K 100 100 000 - 213
192 Power-Off_Retract_Count -O---K 252 252 000 - 0
194 Temperature_Celsius -O---- 064 042 000 - 35 (Min/Max 10/58)
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
197 Current_Pending_Sector -O--CK 252 100 000 - 0
198 Offline_Uncorrectable ----CK 252 252 000 - 0
199 UDMA_CRC_Error_Count -OS-CK 100 100 000 - 38
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 13188
223 Load_Retry_Count -O--CK 100 100 000 - 259
225 Load_Cycle_Count -O--CK 077 077 000 - 235446
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 2 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xc0-0xdf GPL,SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
Device Error Count: 24598 (device log contains only the most recent 8 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 24598 [5] occurred at disk power-on lifetime: 19480 hours (811 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 02 5c 7e 88 40 00
Error: UNC 8 sectors at LBA = 0x025c7e88 = 39616136
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 03 00 08 00 00 02 5c 7e 88 40 00 00:00:00.379 READ DMA EXT
25 00 03 00 08 00 00 01 1f e5 68 40 00 00:00:00.379 READ DMA EXT
25 00 03 00 08 00 00 00 b1 a9 38 40 00 00:00:00.379 READ DMA EXT
25 00 03 00 08 00 00 00 6a f7 f0 40 00 00:00:00.379 READ DMA EXT
25 00 03 00 08 00 00 00 6a f7 f8 40 00 00:00:00.379 READ DMA EXT
Error 24597 [4] occurred at disk power-on lifetime: 19480 hours (811 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 02 5c 7e 88 40 00
Error: UNC 8 sectors at LBA = 0x025c7e88 = 39616136
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 03 00 08 00 00 02 5c 7e 88 40 00 00:00:00.377 READ DMA EXT
25 00 03 00 08 00 00 01 1f e5 68 40 00 00:00:00.377 READ DMA EXT
25 00 03 00 08 00 00 00 b1 a9 38 40 00 00:00:00.377 READ DMA EXT
25 00 03 00 08 00 00 00 6a f7 f0 40 00 00:00:00.377 READ DMA EXT
25 00 03 00 08 00 00 00 6a f7 f8 40 00 00:00:00.377 READ DMA EXT
Error 24596 [3] occurred at disk power-on lifetime: 19480 hours (811 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 02 5c 7e 88 40 00
Error: UNC 8 sectors at LBA = 0x025c7e88 = 39616136
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 03 00 08 00 00 02 5c 7e 88 40 00 00:00:00.375 READ DMA EXT
25 00 03 00 08 00 00 01 1f e5 68 40 00 00:00:00.375 READ DMA EXT
25 00 03 00 08 00 00 00 b1 a9 38 40 00 00:00:00.375 READ DMA EXT
25 00 03 00 08 00 00 00 6a f7 f0 40 00 00:00:00.375 READ DMA EXT
25 00 03 00 08 00 00 00 6a f7 f8 40 00 00:00:00.375 READ DMA EXT
Error 24595 [2] occurred at disk power-on lifetime: 19480 hours (811 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 02 5c 7e 88 40 00
Error: UNC 8 sectors at LBA = 0x025c7e88 = 39616136
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 03 00 08 00 00 02 5c 7e 88 40 00 00:00:00.373 READ DMA EXT
25 00 03 00 08 00 00 01 1f e5 68 40 00 00:00:00.373 READ DMA EXT
25 00 03 00 08 00 00 00 b1 a9 38 40 00 00:00:00.373 READ DMA EXT
25 00 03 00 08 00 00 00 6a f7 f0 40 00 00:00:00.373 READ DMA EXT
25 00 03 00 08 00 00 00 6a f7 f8 40 00 00:00:00.373 READ DMA EXT
Error 24594 [1] occurred at disk power-on lifetime: 19480 hours (811 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 02 5c 7e 88 40 00
Error: UNC 8 sectors at LBA = 0x025c7e88 = 39616136
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 03 00 08 00 00 02 5c 7e 88 40 00 00:00:00.371 READ DMA EXT
25 00 03 00 08 00 00 01 1f e5 68 40 00 00:00:00.371 READ DMA EXT
25 00 03 00 08 00 00 00 b1 a9 38 40 00 00:00:00.371 READ DMA EXT
25 00 03 00 08 00 00 00 6a f7 f0 40 00 00:00:00.371 READ DMA EXT
25 00 03 00 08 00 00 00 6a f7 f8 40 00 00:00:00.371 READ DMA EXT
Error 24593 [0] occurred at disk power-on lifetime: 19480 hours (811 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 02 5c 7e 88 40 00
Error: UNC 8 sectors at LBA = 0x025c7e88 = 39616136
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 03 00 08 00 00 02 5c 7e 88 40 00 00:00:00.369 READ DMA EXT
25 00 03 00 08 00 00 01 1f e5 68 40 00 00:00:00.369 READ DMA EXT
25 00 03 00 08 00 00 00 b1 a9 38 40 00 00:00:00.369 READ DMA EXT
25 00 03 00 08 00 00 00 6a f7 f0 40 00 00:00:00.369 READ DMA EXT
25 00 03 00 08 00 00 00 6a f7 f8 40 00 00:00:00.369 READ DMA EXT
Error 24592 [7] occurred at disk power-on lifetime: 19480 hours (811 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 02 5c 7e 88 40 00
Error: UNC 8 sectors at LBA = 0x025c7e88 = 39616136
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 03 00 08 00 00 02 5c 7e 88 40 00 00:00:00.367 READ DMA EXT
25 00 03 00 08 00 00 01 1f e5 68 40 00 00:00:00.367 READ DMA EXT
25 00 03 00 08 00 00 00 b1 a9 38 40 00 00:00:00.367 READ DMA EXT
25 00 03 00 08 00 00 00 6a f7 f0 40 00 00:00:00.367 READ DMA EXT
25 00 03 00 08 00 00 00 6a f7 f8 40 00 00:00:00.367 READ DMA EXT
Error 24591 [6] occurred at disk power-on lifetime: 19480 hours (811 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 02 5c 7e 88 40 00
Error: UNC 8 sectors at LBA = 0x025c7e88 = 39616136
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 03 00 08 00 00 02 5c 7e 88 40 00 00:00:00.365 READ DMA EXT
25 00 03 00 08 00 00 01 1f e5 68 40 00 00:00:00.365 READ DMA EXT
25 00 03 00 08 00 00 00 b1 a9 38 40 00 00:00:00.365 READ DMA EXT
25 00 03 00 08 00 00 00 6a f7 f0 40 00 00:00:00.365 READ DMA EXT
25 00 03 00 08 00 00 00 6a f7 f8 40 00 00:00:00.365 READ DMA EXT
SMART Extended Self-test Log Version: 1 (2 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0x50) Completed without error 00% 12745 -
# 2 Short offline Completed: read failure 90% 12745 1882294976
# 3 Vendor (0x50) Completed without error 00% 11478 -
# 4 Short offline Completed: read failure 90% 11478 1882294976
# 5 Vendor (0x50) Completed without error 00% 11058 -
# 6 Short offline Completed: read failure 90% 11058 1882294976
# 7 Vendor (0x50) Completed without error 00% 9220 -
# 8 Short offline Completed: read failure 90% 9220 1882294976
# 9 Vendor (0x50) Completed without error 00% 8106 -
#10 Short offline Completed without error 00% 8106 -
#11 Vendor (0x50) Aborted by host 90% 7471 -
#12 Short offline Completed without error 00% 7471 -
#13 Vendor (0x50) Completed without error 00% 6871 -
#14 Short offline Completed without error 00% 6871 -
#15 Vendor (0x50) Completed without error 00% 3440 -
#16 Short offline Completed without error 00% 3440 -
#17 Vendor (0x50) Completed without error 00% 2451 -
#18 Short offline Completed without error 00% 2451 -
#19 Vendor (0x50) Completed without error 00% 1183 -
#20 Short offline Completed without error 00% 1183 -
#21 Vendor (0x50) Completed without error 00% 326 -
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Completed [00% left] (0-65535)
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: 28/35 Celsius
Lifetime Min/Max Temperature: 10/58 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 5 minutes
Temperature Logging Interval: 5 minutes
Min/Max recommended Temperature: -5/80 Celsius
Min/Max Temperature Limit: -10/85 Celsius
Temperature History Size (Index): 128 (15)
Index Estimated Time Temperature Celsius
16 2024-03-25 07:10 35 ****************
17 2024-03-25 07:15 32 *************
18 2024-03-25 07:20 25 ******
19 2024-03-25 07:25 29 **********
20 2024-03-25 07:30 34 ***************
21 2024-03-25 07:35 36 *****************
22 2024-03-25 07:40 37 ******************
23 2024-03-25 07:45 26 *******
24 2024-03-25 07:50 30 ***********
25 2024-03-25 07:55 34 ***************
26 2024-03-25 08:00 35 ****************
27 2024-03-25 08:05 37 ******************
28 2024-03-25 08:10 31 ************
29 2024-03-25 08:15 32 *************
30 2024-03-25 08:20 35 ****************
31 2024-03-25 08:25 36 *****************
32 2024-03-25 08:30 37 ******************
33 2024-03-25 08:35 26 *******
34 2024-03-25 08:40 29 **********
35 2024-03-25 08:45 32 *************
36 2024-03-25 08:50 33 **************
37 2024-03-25 08:55 34 ***************
38 2024-03-25 09:00 26 *******
39 2024-03-25 09:05 30 ***********
40 2024-03-25 09:10 32 *************
41 2024-03-25 09:15 33 **************
42 2024-03-25 09:20 33 **************
43 2024-03-25 09:25 26 *******
44 2024-03-25 09:30 28 *********
45 2024-03-25 09:35 29 **********
46 2024-03-25 09:40 31 ************
47 2024-03-25 09:45 32 *************
48 2024-03-25 09:50 33 **************
49 2024-03-25 09:55 33 **************
50 2024-03-25 10:00 34 ***************
... ..( 8 skipped). .. ***************
59 2024-03-25 10:45 34 ***************
60 2024-03-25 10:50 26 *******
61 2024-03-25 10:55 28 *********
62 2024-03-25 11:00 29 **********
63 2024-03-25 11:05 31 ************
64 2024-03-25 11:10 32 *************
65 2024-03-25 11:15 29 **********
66 2024-03-25 11:20 31 ************
67 2024-03-25 11:25 32 *************
68 2024-03-25 11:30 33 **************
69 2024-03-25 11:35 33 **************
70 2024-03-25 11:40 34 ***************
... ..( 10 skipped). .. ***************
81 2024-03-25 12:35 34 ***************
82 2024-03-25 12:40 26 *******
83 2024-03-25 12:45 27 ********
84 2024-03-25 12:50 31 ************
85 2024-03-25 12:55 31 ************
86 2024-03-25 13:00 32 *************
87 2024-03-25 13:05 32 *************
88 2024-03-25 13:10 33 **************
... ..( 3 skipped). .. **************
92 2024-03-25 13:30 33 **************
93 2024-03-25 13:35 27 ********
94 2024-03-25 13:40 28 *********
95 2024-03-25 13:45 29 **********
96 2024-03-25 13:50 30 ***********
97 2024-03-25 13:55 30 ***********
98 2024-03-25 14:00 31 ************
... ..( 4 skipped). .. ************
103 2024-03-25 14:25 31 ************
104 2024-03-25 14:30 32 *************
... ..( 4 skipped). .. *************
109 2024-03-25 14:55 32 *************
110 2024-03-25 15:00 33 **************
... ..( 9 skipped). .. **************
120 2024-03-25 15:50 33 **************
121 2024-03-25 15:55 34 ***************
122 2024-03-25 16:00 30 ***********
123 2024-03-25 16:05 32 *************
124 2024-03-25 16:10 33 **************
125 2024-03-25 16:15 34 ***************
126 2024-03-25 16:20 34 ***************
127 2024-03-25 16:25 35 ****************
... ..( 3 skipped). .. ****************
3 2024-03-25 16:45 35 ****************
4 2024-03-25 16:50 30 ***********
5 2024-03-25 16:55 31 ************
6 2024-03-25 17:00 32 *************
7 2024-03-25 17:05 33 **************
8 2024-03-25 17:10 33 **************
9 2024-03-25 17:15 34 ***************
10 2024-03-25 17:20 34 ***************
11 2024-03-25 17:25 34 ***************
12 2024-03-25 17:30 35 ****************
... ..( 2 skipped). .. ****************
15 2024-03-25 17:45 35 ****************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0002 4 0 R_ERR response for data FIS
0x0003 4 0 R_ERR response for device-to-host data FIS
0x0004 4 0 R_ERR response for host-to-device data FIS
0x0005 4 0 R_ERR response for non-data FIS
0x0006 4 0 R_ERR response for device-to-host non-data FIS
0x0007 4 0 R_ERR response for host-to-device non-data FIS
0x0008 4 0 Device-to-host non-data FIS retries
0x0009 4 5 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 4 Device-to-host register FISes sent due to a COMRESET
0x000b 4 0 CRC errors within host-to-device FIS
0x000d 4 0 Non-CRC errors within host-to-device FIS
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x8e00 4 0 Vendor specific
0x8e01 4 0 Vendor specific
0x8e02 4 0 Vendor specific
0x8e03 4 0 Vendor specific
0x8e04 4 0 Vendor specific
0x8e05 4 0 Vendor specific
0x8e06 4 0 Vendor specific
0x8e07 4 0 Vendor specific
0x8e08 4 0 Vendor specific
0x8e09 4 0 Vendor specific
0x8e0a 4 0 Vendor specific
0x8e0b 4 0 Vendor specific
0x8e0c 4 0 Vendor specific
0x8e0d 4 0 Vendor specific
0x8e0e 4 0 Vendor specific
0x8e0f 4 0 Vendor specific
0x8e10 4 0 Vendor specific
0x8e11 4 0 Vendor specific