Probe #46a601320b of Dell Inspiron N4030

Log: smartctl

/dev/sda === START OF INFORMATION SECTION === Model Family: Seagate Momentus 5400.3 Device Model: ST9120822AS Serial Number: -- Firmware Version: 3.ALC User Capacity: 120.034.123.776 bytes [120 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA/ATAPI-7 (minor revision not indicated) Local Time is: Thu Aug 11 22:19:20 2016 BRT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 254 (maximum performance) Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 426) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 111) minutes. SCT capabilities: (0x0001) SCT Status supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 100 060 006 - 619464 3 Spin_Up_Time PO---- 099 099 000 - 0 4 Start_Stop_Count -O--CK 097 097 020 - 3272 5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0 7 Seek_Error_Rate POSR-- 072 060 030 - 34503610932 9 Power_On_Hours -O--CK 096 096 000 - 3843 10 Spin_Retry_Count PO--C- 100 100 034 - 0 12 Power_Cycle_Count -O--CK 097 097 020 - 3471 187 Reported_Uncorrect -O--CK 001 001 000 - 393 189 High_Fly_Writes -O-RCK 096 096 000 - 4 190 Airflow_Temperature_Cel -O---K 079 040 045 Past 21 (1 153 22 19 0) 192 Power-Off_Retract_Count -O--CK 099 099 000 - 2730 193 Load_Cycle_Count -O--CK 066 066 000 - 69341 194 Temperature_Celsius -O---K 021 060 000 - 21 (0 14 0 0 0) 195 Hardware_ECC_Recovered -O-RC- 066 051 000 - 179743099 197 Current_Pending_Sector -O--C- 100 100 000 - 2 198 Offline_Uncorrectable ----C- 100 100 000 - 2 199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0 200 Multi_Zone_Error_Rate ------ 100 253 000 - 0 202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory not supported SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 SL R/O 5 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 SL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 SL R/O 1 SATA NCQ Queued Error log 0x11 SL R/O 1 SATA Phy Event Counters log 0x20 SL R/O 1 Streaming performance log [OBS-8] 0x21 SL R/O 1 Write stream error log 0x22 SL R/O 1 Read stream error log 0x23 SL R/O 1 Delayed sector log [OBS-8] 0x80-0x9f SL R/W 16 Host vendor specific log 0xa0 SL VS 1 Device vendor specific log 0xa1 SL VS 20 Device vendor specific log 0xa2 SL VS 101 Device vendor specific log 0xa8 SL VS 20 Device vendor specific log 0xa9 SL VS 1 Device vendor specific log 0xe0 SL R/W 1 SCT Command/Status 0xe1 SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log (GP Log 0x03) not supported SMART Error Log Version: 1 ATA Error Count: 418 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 418 occurred at disk power-on lifetime: 3103 hours (129 days + 7 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 fe 39 2d e6 Error: UNC at LBA = 0x062d39fe = 103627262 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 f8 39 2d e6 00 00:15:23.120 READ DMA c8 00 20 e0 c3 2f ed 00 00:15:25.388 READ DMA c8 00 20 78 b6 c4 eb 00 00:15:25.373 READ DMA 27 00 00 00 00 00 e0 00 00:15:25.354 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] ec 00 00 00 00 00 a0 00 00:15:25.354 IDENTIFY DEVICE Error 417 occurred at disk power-on lifetime: 3103 hours (129 days + 7 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 fe 39 2d e6 Error: UNC at LBA = 0x062d39fe = 103627262 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 f8 39 2d e6 00 00:15:23.120 READ DMA c8 00 08 b8 93 31 e6 00 00:15:23.120 READ DMA c8 00 08 b0 93 31 e6 00 00:15:23.111 READ DMA c8 00 08 a8 93 31 e6 00 00:15:23.110 READ DMA c8 00 08 a0 93 31 e6 00 00:15:23.110 READ DMA Error 416 occurred at disk power-on lifetime: 3103 hours (129 days + 7 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 fe 39 2d e6 Error: UNC at LBA = 0x062d39fe = 103627262 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 f8 39 2d e6 00 00:15:18.254 READ DMA e7 00 00 00 00 00 a0 00 00:15:18.254 FLUSH CACHE 27 00 00 00 00 00 e0 00 00:15:18.254 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] ec 00 00 00 00 00 a0 00 00:15:18.253 IDENTIFY DEVICE ef 03 46 00 00 00 a0 00 00:15:18.252 SET FEATURES [Set transfer mode] Error 415 occurred at disk power-on lifetime: 3103 hours (129 days + 7 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 fe 39 2d e6 Error: UNC at LBA = 0x062d39fe = 103627262 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 f8 39 2d e6 00 00:15:18.254 READ DMA ca 00 08 d8 86 ab eb 00 00:15:18.254 WRITE DMA e7 00 00 00 00 00 a0 00 00:15:18.254 FLUSH CACHE ca 00 08 60 74 8a ea 00 00:15:18.253 WRITE DMA ca 00 08 d8 2c 8a ea 00 00:15:18.252 WRITE DMA Error 414 occurred at disk power-on lifetime: 3103 hours (129 days + 7 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 fe 39 2d e6 Error: UNC at LBA = 0x062d39fe = 103627262 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 f8 39 2d e6 00 00:15:13.730 READ DMA ca 00 20 00 08 08 ed 00 00:15:13.730 WRITE DMA ca 00 28 80 71 f7 ec 00 00:15:15.970 WRITE DMA ca 00 10 60 85 f2 ec 00 00:15:15.969 WRITE DMA 35 00 28 b0 85 ab e0 00 00:15:15.969 WRITE DMA EXT SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test log structure revision number 1 SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 2 SCT Version (vendor specific): 521 (0x0209) SCT Support Level: 1 Device State: Active (0) Current Temperature: 21 Celsius Power Cycle Max Temperature: 0 Celsius Lifetime Max Temperature: 0 Celsius SCT Data Table command not supported SCT Error Recovery Control command not supported Device Statistics (GP/SMART Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x000a 2 17 Device-to-host register FISes sent due to a COMRESET 0x0001 2 0 Command failed due to ICRC error 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0009 2 22 Transition from drive PhyRdy to drive PhyNRdy 0x8002 2 0 Vendor specific 0x8003 2 5 Vendor specific 0x8004 2 0 Vendor specific


Hardware for Linux and BSD

GitHub