Probe #714801f458 of Google Redrix
Log: smartctl
/dev/nvme0n1
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.14.0-23-generic] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PSEDN128GA17DC0
Serial Number: --
Firmware Version: HP000006
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 128,035,676,160 [128 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sun Jul 13 12:06:35 2025 +0330
Firmware Updates (0x06): 3 Slots
Optional Admin Commands (0x001f): Security Format Frmw_DL NS_Mngmt Self_Test
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 85 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0020W - - 4 4 4 4 5000 45000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 36 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 4%
Data Units Read: 13,090,164 [6.70 TB]
Data Units Written: 13,299,056 [6.80 TB]
Host Read Commands: 142,743,844
Host Write Commands: 127,064,740
Controller Busy Time: 6,058
Power Cycles: 1,219
Power On Hours: 2,925
Unsafe Shutdowns: 232
Media and Data Integrity Errors: 0
Error Information Log Entries: 735
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 42 Celsius
Temperature Sensor 2: 68 Celsius
Error Information (NVMe Log 0x01, 16 of 64 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
0 735 0 0x6014 0x4005 - 0 0 - Invalid Field in Command
1 734 0 0x5017 0x4005 - 0 0 - Invalid Field in Command
2 733 0 0x5015 0x4005 - 0 0 - Invalid Field in Command
3 732 0 0x1009 0x4005 - 0 0 - Invalid Field in Command
4 731 0 0x8001 0x4005 0x004 0 1 - Invalid Field in Command
5 730 0 0x3010 0x4004 - 0 0 - Invalid Field in Command
6 729 0 0x2013 0x4004 - 0 0 - Invalid Field in Command
7 728 0 0x2011 0x4004 - 0 0 - Invalid Field in Command
8 727 0 0x2010 0x4004 - 0 0 - Invalid Field in Command
9 726 0 0x0010 0x4005 0x028 0 0 - Invalid Field in Command
Read Self-test Log failed: Invalid Field in Command (0x2002)