/dev/sda
=== START OF INFORMATION SECTION ===
Model Family: Toshiba 3.5" HDD DT01ACA...
Device Model: TOSHIBA DT01ACA200
Serial Number: --
LU WWN Device Id: 5 000039 ...
Firmware Version: MX4OABB0
User Capacity: 2 000 398 934 016 bytes [2,00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Apr 6 21:32:14 2016 YEKT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (14822) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 247) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
2 Throughput_Performance P-S--- 140 140 054 - 68
3 Spin_Up_Time POS--- 140 140 024 - 285 (Average 257)
4 Start_Stop_Count -O--C- 100 100 000 - 2033
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
8 Seek_Time_Performance P-S--- 124 124 020 - 33
9 Power_On_Hours -O--C- 100 100 000 - 2185
10 Spin_Retry_Count PO--C- 100 100 060 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 1721
192 Power-Off_Retract_Count -O--CK 099 099 000 - 2033
193 Load_Cycle_Count -O--C- 099 099 000 - 2033
194 Temperature_Celsius -O---- 157 157 000 - 38 (Min/Max 22/42)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O---K 100 100 000 - 0
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 1
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL R/O 7 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters
0x20 GPL R/O 1 Streaming performance log [OBS-8]
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
Device Error Count: 1
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 1 [0] occurred at disk power-on lifetime: 1 hours (0 days + 1 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 09 00 00 05 6d ff ef 05 00
Error: ICRC, ABRT at LBA = 0x056dffef = 91095023
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 50 00 00 05 6d ff f8 40 00 00:27:44.281 READ FPDMA QUEUED
60 00 f8 00 48 00 00 05 6d ff 00 40 00 00:27:44.281 READ FPDMA QUEUED
60 00 08 00 40 00 00 05 6d fe f8 40 00 00:27:44.281 READ FPDMA QUEUED
60 00 f8 00 38 00 00 05 6d fe 00 40 00 00:27:44.281 READ FPDMA QUEUED
60 00 08 00 30 00 00 05 6d fd f8 40 00 00:27:44.280 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
SCT Support Level: 1
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 37 Celsius
Power Cycle Min/Max Temperature: 25/38 Celsius
Lifetime Min/Max Temperature: 22/42 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/70 Celsius
Temperature History Size (Index): 128 (31)
Index Estimated Time Temperature Celsius
32 2016-04-06 19:25 34 ***************
33 2016-04-06 19:26 35 ****************
... ..( 2 skipped). .. ****************
36 2016-04-06 19:29 35 ****************
37 2016-04-06 19:30 36 *****************
... ..( 2 skipped). .. *****************
40 2016-04-06 19:33 36 *****************
41 2016-04-06 19:34 ? -
42 2016-04-06 19:35 24 *****
43 2016-04-06 19:36 25 ******
44 2016-04-06 19:37 25 ******
45 2016-04-06 19:38 26 *******
46 2016-04-06 19:39 26 *******
47 2016-04-06 19:40 26 *******
48 2016-04-06 19:41 27 ********
49 2016-04-06 19:42 27 ********
50 2016-04-06 19:43 28 *********
... ..( 2 skipped). .. *********
53 2016-04-06 19:46 28 *********
54 2016-04-06 19:47 29 **********
55 2016-04-06 19:48 ? -
56 2016-04-06 19:49 26 *******
57 2016-04-06 19:50 26 *******
58 2016-04-06 19:51 27 ********
59 2016-04-06 19:52 27 ********
60 2016-04-06 19:53 28 *********
61 2016-04-06 19:54 28 *********
62 2016-04-06 19:55 29 **********
63 2016-04-06 19:56 29 **********
64 2016-04-06 19:57 29 **********
65 2016-04-06 19:58 30 ***********
66 2016-04-06 19:59 30 ***********
67 2016-04-06 20:00 30 ***********
68 2016-04-06 20:01 31 ************
69 2016-04-06 20:02 31 ************
70 2016-04-06 20:03 31 ************
71 2016-04-06 20:04 32 *************
... ..( 2 skipped). .. *************
74 2016-04-06 20:07 32 *************
75 2016-04-06 20:08 33 **************
... ..( 2 skipped). .. **************
78 2016-04-06 20:11 33 **************
79 2016-04-06 20:12 34 ***************
... ..( 4 skipped). .. ***************
84 2016-04-06 20:17 34 ***************
85 2016-04-06 20:18 35 ****************
... ..( 7 skipped). .. ****************
93 2016-04-06 20:26 35 ****************
94 2016-04-06 20:27 36 *****************
... ..( 13 skipped). .. *****************
108 2016-04-06 20:41 36 *****************
109 2016-04-06 20:42 37 ******************
... ..( 12 skipped). .. ******************
122 2016-04-06 20:55 37 ******************
123 2016-04-06 20:56 38 *******************
124 2016-04-06 20:57 37 ******************
... ..( 2 skipped). .. ******************
127 2016-04-06 21:00 37 ******************
0 2016-04-06 21:01 38 *******************
1 2016-04-06 21:02 38 *******************
2 2016-04-06 21:03 38 *******************
3 2016-04-06 21:04 37 ******************
4 2016-04-06 21:05 38 *******************
5 2016-04-06 21:06 37 ******************
... ..( 5 skipped). .. ******************
11 2016-04-06 21:12 37 ******************
12 2016-04-06 21:13 38 *******************
13 2016-04-06 21:14 37 ******************
... ..( 10 skipped). .. ******************
24 2016-04-06 21:25 37 ******************
25 2016-04-06 21:26 38 *******************
26 2016-04-06 21:27 38 *******************
27 2016-04-06 21:28 37 ******************
... ..( 3 skipped). .. ******************
31 2016-04-06 21:32 37 ******************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP Log 0x04)
Page Offset Size Value Description
1 ===== = = == General Statistics (rev 1) ==
1 0x008 4 1721 Lifetime Power-On Resets
1 0x010 4 2185 Power-on Hours
1 0x018 6 8043773183 Logical Sectors Written
1 0x020 6 30067233 Number of Write Commands
1 0x028 6 17752623713 Logical Sectors Read
1 0x030 6 94920917 Number of Read Commands
3 ===== = = == Rotating Media Statistics (rev 1) ==
3 0x008 4 2048 Spindle Motor Power-on Hours
3 0x010 4 2048 Head Flying Hours
3 0x018 4 2033 Head Load Events
3 0x020 4 0 Number of Reallocated Logical Sectors
3 0x028 4 3 Read Recovery Attempts
3 0x030 4 6 Number of Mechanical Start Failures
4 ===== = = == General Errors Statistics (rev 1) ==
4 0x008 4 0 Number of Reported Uncorrectable Errors
4 0x010 4 2 Resets Between Cmd Acceptance and Completion
5 ===== = = == Temperature Statistics (rev 1) ==
5 0x008 1 37 Current Temperature
5 0x010 1 36~ Average Short Term Temperature
5 0x018 1 32~ Average Long Term Temperature
5 0x020 1 42 Highest Temperature
5 0x028 1 22 Lowest Temperature
5 0x030 1 37~ Highest Average Short Term Temperature
5 0x038 1 25~ Lowest Average Short Term Temperature
5 0x040 1 36~ Highest Average Long Term Temperature
5 0x048 1 25~ Lowest Average Long Term Temperature
5 0x050 4 0 Time in Over-Temperature
5 0x058 1 60 Specified Maximum Operating Temperature
5 0x060 4 0 Time in Under-Temperature
5 0x068 1 0 Specified Minimum Operating Temperature
6 ===== = = == Transport Statistics (rev 1) ==
6 0x008 4 2006 Number of Hardware Resets
6 0x010 4 366 Number of ASR Events
6 0x018 4 1 Number of Interface CRC Errors
|_ ~ normalized value
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0009 2 39 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 39 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
/dev/sdb
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.7 and 7200.7 Plus
Device Model: ST3120026AS
Serial Number: --
Firmware Version: 3.18
User Capacity: 120 033 041 920 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-6 T13/1410D revision 2
Local Time is: Wed Apr 6 21:32:19 2016 YEKT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 85) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 064 057 006 - 156431947
3 Spin_Up_Time PO---- 096 096 000 - 0
4 Start_Stop_Count -O--CK 100 100 020 - 32
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 088 060 030 - 694234901
9 Power_On_Hours -O--CK 085 085 000 - 13772
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 091 091 020 - 9844
194 Temperature_Celsius -O---K 045 064 000 - 45
195 Hardware_ECC_Recovered -O-RC- 064 057 000 - 156431947
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 072 000 - 180
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL,SL VS 1 Device vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL,SL VS 101 Device vendor specific log
0xa8 GPL,SL VS 20 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xff GPL - 24064 Reserved
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11) not supported