Probe #ad135e2748 of Dell 0X8DXD A01 Desktop Computer (Precision 5820 Tower)

Log: smartctl

/dev/nvme0n1 smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.14.2-desktop-3omv2590] (OpenMandriva Lx 7.4-1) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: SAMSUNG MZVLB512HAJQ-000H1 Serial Number: -- Firmware Version: EXA72H1Q PCI Vendor/Subsystem ID: 0x144d IEEE OUI Identifier: 0x002538 Total NVM Capacity: 512,110,190,592 [512 GB] Unallocated NVM Capacity: 0 Controller ID: 4 NVMe Version: 1.2 Number of Namespaces: 1 Namespace 1 Size/Capacity: 512,110,190,592 [512 GB] Namespace 1 Utilization: 227,473,235,968 [227 GB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 002538 ... Local Time is: Mon Jul 14 07:59:48 2025 BST Firmware Updates (0x16): 3 Slots, no Reset required Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg Maximum Data Transfer Size: 512 Pages Warning Comp. Temp. Threshold: 81 Celsius Critical Comp. Temp. Threshold: 82 Celsius Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 7.02W - - 0 0 0 0 0 0 1 + 6.30W - - 1 1 1 1 0 0 2 + 3.50W - - 2 2 2 2 0 0 3 - 0.0760W - - 3 3 3 3 210 1200 4 - 0.0050W - - 4 4 4 4 2000 8000 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 0 1 - 4096 0 0 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 25 Celsius Available Spare: 100% Available Spare Threshold: 5% Percentage Used: 7% Data Units Read: 36,980,183 [18.9 TB] Data Units Written: 131,919,639 [67.5 TB] Host Read Commands: 1,086,786,525 Host Write Commands: 5,231,610,867 Controller Busy Time: 8,466 Power Cycles: 2,085 Power On Hours: 12,192 Unsafe Shutdowns: 489 Media and Data Integrity Errors: 0 Error Information Log Entries: 11,519 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Temperature Sensor 1: 25 Celsius Temperature Sensor 2: 25 Celsius Error Information (NVMe Log 0x01, 16 of 256 entries) Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message 0 11519 0 0x0004 0x4004 - 0 0 - Invalid Field in Command Self-test Log (NVMe Log 0x06) Self-test status: No self-test in progress Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code 0 Short Aborted: Self-test command 12134 - - - - - 1 Short Aborted: Self-test command 12080 - - - - - 2 Short Aborted: Self-test command 12036 - - - - - 3 Short Completed without error 12035 - - - - - 4 Short Completed without error 11993 - - - - - 5 Short Aborted: Self-test command 11970 - - - - - 6 Extended Completed without error 11965 - - - - - 7 Short Completed without error 11964 - - - - - 8 Extended Aborted: Self-test command 11960 - - - - - 9 Short Completed without error 11960 - - - - - 10 Short Completed without error 11948 - - - - - 11 Short Completed without error 11947 - - - - - 12 Short Completed without error 11945 - - - - - /dev/nvme1n1 smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.14.2-desktop-3omv2590] (OpenMandriva Lx 7.4-1) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: SAMSUNG MZVLB512HAJQ-000L7 Serial Number: -- Firmware Version: 5L2QEXA7 PCI Vendor/Subsystem ID: 0x144d IEEE OUI Identifier: 0x002538 Total NVM Capacity: 512,110,190,592 [512 GB] Unallocated NVM Capacity: 0 Controller ID: 4 NVMe Version: 1.2 Number of Namespaces: 1 Namespace 1 Size/Capacity: 512,110,190,592 [512 GB] Namespace 1 Utilization: 126,400,040,960 [126 GB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 002538 ... Local Time is: Mon Jul 14 07:59:48 2025 BST Firmware Updates (0x16): 3 Slots, no Reset required Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg Maximum Data Transfer Size: 512 Pages Warning Comp. Temp. Threshold: 81 Celsius Critical Comp. Temp. Threshold: 82 Celsius Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 7.02W - - 0 0 0 0 0 0 1 + 6.30W - - 1 1 1 1 0 0 2 + 3.50W - - 2 2 2 2 0 0 3 - 0.0760W - - 3 3 3 3 210 1200 4 - 0.0050W - - 4 4 4 4 2000 8000 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 0 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 26 Celsius Available Spare: 100% Available Spare Threshold: 10% Percentage Used: 1% Data Units Read: 17,185,216 [8.79 TB] Data Units Written: 26,284,979 [13.4 TB] Host Read Commands: 245,800,112 Host Write Commands: 409,680,593 Controller Busy Time: 1,705 Power Cycles: 2,882 Power On Hours: 1,760 Unsafe Shutdowns: 609 Media and Data Integrity Errors: 0 Error Information Log Entries: 12,328 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Temperature Sensor 1: 26 Celsius Temperature Sensor 2: 26 Celsius Error Information (NVMe Log 0x01, 16 of 64 entries) Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message 0 12328 0 0x0010 0x4004 - 0 0 - Invalid Field in Command Self-test Log (NVMe Log 0x06) Self-test status: No self-test in progress Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code 0 Short Aborted: Self-test command 1752 - - - - - 1 Short Aborted: Self-test command 1747 - - - - - 2 Short Aborted: Self-test command 1672 - - - - - 3 Short Completed without error 1671 - - - - - 4 Short Completed without error 1624 - - - - - 5 Short Aborted: Self-test command 1583 - - - - - 6 Extended Completed without error 1578 - - - - - 7 Short Completed without error 1578 - - - - - 8 Extended Aborted: Self-test command 1574 - - - - - 9 Short Completed without error 1574 - - - - - 10 Short Completed without error 1564 - - - - - 11 Short Completed without error 1562 - - - - - 12 Short Completed without error 1561 - - - - - 13 Short Aborted: Self-test command 1549 - - - - - 14 Short Completed without error 1549 - - - - - 15 Short Completed without error 1549 - - - - - 16 Short Completed without error 1549 - - - - - /dev/sda smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.14.2-desktop-3omv2590] (OpenMandriva Lx 7.4-1) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Toshiba 3.5" DT01ACA... Desktop HDD Device Model: TOSHIBA DT01ACA200 Serial Number: -- LU WWN Device Id: 5 000039 ... Firmware Version: MX4OAC60 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: In smartctl database ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon Jul 14 07:59:48 2025 BST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Disabled Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (14631) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 244) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 100 100 016 - 0 2 Throughput_Performance POS--K 139 100 054 - 70 3 Spin_Up_Time PO---K 131 100 024 - 294 (Average 282) 4 Start_Stop_Count -O--CK 100 100 000 - 2281 5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0 7 Seek_Error_Rate POSR-K 100 100 067 - 0 8 Seek_Time_Performance P-S--K 124 100 020 - 33 9 Power_On_Hours -O--CK 096 096 000 - 32507 10 Spin_Retry_Count PO--CK 100 100 060 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 2106 183 Runtime_Bad_Block -O--CK 100 100 000 - 0 184 End-to-End_Error PO--CK 100 100 097 - 0 185 Unknown_Attribute -O--CK 100 100 000 - 44035 187 Reported_Uncorrect -O--CK 100 100 000 - 0 188 Command_Timeout -O--CK 100 100 000 - 34363277312 189 High_Fly_Writes -O-RCK 100 100 000 - 0 190 Airflow_Temperature_Cel -O---K 065 058 000 - 35 (Min/Max 24/36) 192 Power-Off_Retract_Count -O--CK 098 098 000 - 3016 193 Load_Cycle_Count -O--CK 098 098 000 - 3016 194 Temperature_Celsius -O---K 171 142 000 - 35 (Min/Max 9/42) 196 Reallocated_Event_Count -O--CK 100 100 000 - 0 197 Current_Pending_Sector -O--CK 100 100 000 - 0 198 Offline_Uncorrectable ----CK 100 100 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL R/O 7 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x12 GPL R/O 1 SATA NCQ Non-Data log 0x20 GPL R/O 1 Streaming performance log 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 30641 - # 2 Short offline Completed without error 00% 30542 - # 3 Short offline Completed without error 00% 30538 - # 4 Short offline Completed without error 00% 30489 - # 5 Short offline Completed without error 00% 30443 - # 6 Short offline Completed without error 00% 30332 - # 7 Short offline Completed without error 00% 30324 - # 8 Short offline Completed without error 00% 30209 - # 9 Short offline Completed without error 00% 30044 - #10 Short offline Completed without error 00% 29925 - #11 Short offline Completed without error 00% 29892 - #12 Short offline Completed without error 00% 29807 - #13 Short offline Completed without error 00% 29797 - #14 Short offline Completed without error 00% 29777 - #15 Short offline Completed without error 00% 29570 - #16 Short offline Completed without error 00% 29466 - #17 Short offline Completed without error 00% 29465 - #18 Short offline Completed without error 00% 29380 - #19 Short offline Completed without error 00% 29379 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) Device State: SMART Off-line Data Collection executing in background (4) Current Temperature: 35 Celsius Power Cycle Min/Max Temperature: 24/36 Celsius Lifetime Min/Max Temperature: 9/42 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -40/70 Celsius Temperature History Size (Index): 128 (34) Index Estimated Time Temperature Celsius 35 2025-07-14 05:52 35 **************** 36 2025-07-14 05:53 35 **************** 37 2025-07-14 05:54 36 ***************** 38 2025-07-14 05:55 35 **************** 39 2025-07-14 05:56 35 **************** 40 2025-07-14 05:57 36 ***************** ... ..( 12 skipped). .. ***************** 53 2025-07-14 06:10 36 ***************** 54 2025-07-14 06:11 ? - 55 2025-07-14 06:12 25 ****** 56 2025-07-14 06:13 25 ****** 57 2025-07-14 06:14 26 ******* 58 2025-07-14 06:15 26 ******* 59 2025-07-14 06:16 27 ******** 60 2025-07-14 06:17 27 ******** 61 2025-07-14 06:18 28 ********* 62 2025-07-14 06:19 28 ********* 63 2025-07-14 06:20 28 ********* 64 2025-07-14 06:21 29 ********** ... ..( 2 skipped). .. ********** 67 2025-07-14 06:24 29 ********** 68 2025-07-14 06:25 30 *********** 69 2025-07-14 06:26 30 *********** 70 2025-07-14 06:27 30 *********** 71 2025-07-14 06:28 31 ************ 72 2025-07-14 06:29 31 ************ 73 2025-07-14 06:30 31 ************ 74 2025-07-14 06:31 32 ************* ... ..( 3 skipped). .. ************* 78 2025-07-14 06:35 32 ************* 79 2025-07-14 06:36 33 ************** ... ..( 10 skipped). .. ************** 90 2025-07-14 06:47 33 ************** 91 2025-07-14 06:48 34 *************** ... ..( 8 skipped). .. *************** 100 2025-07-14 06:57 34 *************** 101 2025-07-14 06:58 35 **************** 102 2025-07-14 06:59 34 *************** ... ..( 5 skipped). .. *************** 108 2025-07-14 07:05 34 *************** 109 2025-07-14 07:06 35 **************** ... ..( 22 skipped). .. **************** 4 2025-07-14 07:29 35 **************** 5 2025-07-14 07:30 36 ***************** ... ..( 4 skipped). .. ***************** 10 2025-07-14 07:35 36 ***************** 11 2025-07-14 07:36 35 **************** ... ..( 22 skipped). .. **************** 34 2025-07-14 07:59 35 **************** SCT Error Recovery Control: Read: 85 (8.5 seconds) Write: 85 (8.5 seconds) Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 2106 --- Lifetime Power-On Resets 0x01 0x010 4 32507 --- Power-on Hours 0x01 0x018 6 20205333825 --- Logical Sectors Written 0x01 0x020 6 25237561 --- Number of Write Commands 0x01 0x028 6 3607705102 --- Logical Sectors Read 0x01 0x030 6 18797685 --- Number of Read Commands 0x03 ===== = = === == Rotating Media Statistics (rev 1) == 0x03 0x008 4 32477 --- Spindle Motor Power-on Hours 0x03 0x010 4 32477 --- Head Flying Hours 0x03 0x018 4 3016 --- Head Load Events 0x03 0x020 4 0 --- Number of Reallocated Logical Sectors 0x03 0x028 4 0 --- Read Recovery Attempts 0x03 0x030 4 6 --- Number of Mechanical Start Failures 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion 0x05 ===== = = === == Temperature Statistics (rev 1) == 0x05 0x008 1 35 --- Current Temperature 0x05 0x010 1 33 N-- Average Short Term Temperature 0x05 0x018 1 33 N-- Average Long Term Temperature 0x05 0x020 1 42 --- Highest Temperature 0x05 0x028 1 9 --- Lowest Temperature 0x05 0x030 1 41 N-- Highest Average Short Term Temperature 0x05 0x038 1 25 N-- Lowest Average Short Term Temperature 0x05 0x040 1 38 N-- Highest Average Long Term Temperature 0x05 0x048 1 25 N-- Lowest Average Long Term Temperature 0x05 0x050 4 0 --- Time in Over-Temperature 0x05 0x058 1 60 --- Specified Maximum Operating Temperature 0x05 0x060 4 0 --- Time in Under-Temperature 0x05 0x068 1 0 --- Specified Minimum Operating Temperature 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 12062 --- Number of Hardware Resets 0x06 0x010 4 10063 --- Number of ASR Events 0x06 0x018 4 0 --- Number of Interface CRC Errors |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 8 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS


Hardware for Linux and BSD

GitHub