Probe #e96260cfb9 of HP EliteBook 2560p

Log: smartctl

/dev/sda smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.12.4-desktop-1omv4050] (OpenMandriva Lx 7.2-2) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: GOODRAM C40 Serial Number: -- Firmware Version: S9FM02.0 User Capacity: 120,034,123,776 bytes [120 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-3 (minor revision not indicated) SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon May 31 18:31:07 2021 BST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Disabled Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 30) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 2) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate -O-R-- 099 099 000 - 31 9 Power_On_Hours -O--C- 100 100 000 - 681 12 Power_Cycle_Count -O--C- 100 100 000 - 601 168 Unknown_Attribute -O--C- 100 100 000 - 0 170 Unknown_Attribute PO--C- 100 100 010 - 43 173 Unknown_Attribute ------ 100 100 000 - 63242268 192 Power-Off_Retract_Count -O--C- 100 100 000 - 50 194 Temperature_Celsius PO---K 070 070 000 - 30 196 Reallocated_Event_Count ------ 100 100 000 - 1 218 Unknown_Attribute ------ 100 100 000 - 0 241 Total_LBAs_Written -O--C- 100 100 000 - 1747423 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 51 Comprehensive SMART error log 0x03 GPL R/O 64 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log SMART Extended Comprehensive Error Log Version: 1 (64 sectors) Device Error Count: 31 CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 31 [30] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 48 00 00 07 47 11 78 e0 00 Error: UNC 72 sectors at LBA = 0x07471178 = 122098040 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 25 00 00 00 48 00 00 07 47 11 78 e0 00 00:37:09.445 READ DMA EXT ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:37:08.457 [VENDOR SPECIFIC] ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:37:08.447 [VENDOR SPECIFIC] 25 00 00 00 48 00 00 07 47 11 78 e0 00 00:36:48.439 READ DMA EXT ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:36:47.449 [VENDOR SPECIFIC] Error 30 [29] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 48 00 00 07 47 11 78 e0 00 Error: UNC 72 sectors at LBA = 0x07471178 = 122098040 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 25 00 00 00 48 00 00 07 47 11 78 e0 00 00:36:48.439 READ DMA EXT ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:36:47.449 [VENDOR SPECIFIC] ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:36:47.439 [VENDOR SPECIFIC] 25 00 00 00 48 00 00 07 47 11 78 e0 00 00:36:27.431 READ DMA EXT ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:36:26.443 [VENDOR SPECIFIC] Error 29 [28] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 48 00 00 07 47 11 78 e0 00 Error: UNC 72 sectors at LBA = 0x07471178 = 122098040 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 25 00 00 00 48 00 00 07 47 11 78 e0 00 00:36:27.431 READ DMA EXT ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:36:26.443 [VENDOR SPECIFIC] ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:36:07.451 [VENDOR SPECIFIC] 25 00 00 00 48 00 00 07 47 11 78 e0 00 00:36:06.424 READ DMA EXT ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:36:05.436 [VENDOR SPECIFIC] Error 28 [27] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 48 00 00 07 47 11 78 e0 00 Error: UNC 72 sectors at LBA = 0x07471178 = 122098040 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 25 00 00 00 48 00 00 07 47 11 78 e0 00 00:36:06.424 READ DMA EXT ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:36:05.436 [VENDOR SPECIFIC] ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:35:46.444 [VENDOR SPECIFIC] 25 00 00 00 48 00 00 07 47 11 78 e0 00 00:35:45.416 READ DMA EXT ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:35:45.344 [VENDOR SPECIFIC] Error 27 [26] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 48 00 00 07 47 11 78 e0 00 Error: UNC 72 sectors at LBA = 0x07471178 = 122098040 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 25 00 00 00 48 00 00 07 47 11 78 e0 00 00:35:45.416 READ DMA EXT ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:35:45.344 [VENDOR SPECIFIC] ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:35:45.334 [VENDOR SPECIFIC] 25 00 00 00 08 00 00 07 47 11 78 e0 00 00:35:25.324 READ DMA EXT ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:35:25.240 [VENDOR SPECIFIC] Error 26 [25] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 08 00 00 07 47 11 78 e0 00 Error: UNC 8 sectors at LBA = 0x07471178 = 122098040 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 25 00 00 00 08 00 00 07 47 11 78 e0 00 00:35:25.324 READ DMA EXT ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:35:25.240 [VENDOR SPECIFIC] ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:35:06.248 [VENDOR SPECIFIC] 25 00 00 00 80 00 00 07 47 11 40 e0 00 00:35:05.221 READ DMA EXT ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:35:05.140 [VENDOR SPECIFIC] Error 25 [24] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 80 00 00 07 47 11 40 e0 00 Error: UNC 128 sectors at LBA = 0x07471140 = 122097984 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 25 00 00 00 80 00 00 07 47 11 40 e0 00 00:35:05.221 READ DMA EXT ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:35:05.140 [VENDOR SPECIFIC] ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:34:46.146 [VENDOR SPECIFIC] 25 00 00 00 08 00 00 07 47 11 78 e0 00 00:34:45.119 READ DMA EXT ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:34:45.039 [VENDOR SPECIFIC] Error 24 [23] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 08 00 00 07 47 11 78 e0 00 Error: UNC 8 sectors at LBA = 0x07471178 = 122098040 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 25 00 00 00 08 00 00 07 47 11 78 e0 00 00:34:45.119 READ DMA EXT ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:34:45.039 [VENDOR SPECIFIC] ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:34:45.029 [VENDOR SPECIFIC] 25 00 00 00 80 00 00 07 47 11 40 e0 00 00:34:25.021 READ DMA EXT ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:34:24.941 [VENDOR SPECIFIC] SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 677 - SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Commands not supported Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 0 --- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 4 9 Transition from drive PhyRdy to drive PhyNRdy 0x000a 4 10 Device-to-host register FISes sent due to a COMRESET 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC


Hardware for Linux and BSD

GitHub