/dev/sda
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.12.4-desktop-1omv4050] (OpenMandriva Lx 7.2-2)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: GOODRAM C40
Serial Number: --
Firmware Version: S9FM02.0
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-3 (minor revision not indicated)
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon May 31 18:31:07 2021 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 30) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 2) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -O-R-- 099 099 000 - 31
9 Power_On_Hours -O--C- 100 100 000 - 681
12 Power_Cycle_Count -O--C- 100 100 000 - 601
168 Unknown_Attribute -O--C- 100 100 000 - 0
170 Unknown_Attribute PO--C- 100 100 010 - 43
173 Unknown_Attribute ------ 100 100 000 - 63242268
192 Power-Off_Retract_Count -O--C- 100 100 000 - 50
194 Temperature_Celsius PO---K 070 070 000 - 30
196 Reallocated_Event_Count ------ 100 100 000 - 1
218 Unknown_Attribute ------ 100 100 000 - 0
241 Total_LBAs_Written -O--C- 100 100 000 - 1747423
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 64 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
Device Error Count: 31
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 31 [30] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 48 00 00 07 47 11 78 e0 00
Error: UNC 72 sectors at LBA = 0x07471178 = 122098040
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 48 00 00 07 47 11 78 e0 00 00:37:09.445 READ DMA EXT
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:37:08.457 [VENDOR SPECIFIC]
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:37:08.447 [VENDOR SPECIFIC]
25 00 00 00 48 00 00 07 47 11 78 e0 00 00:36:48.439 READ DMA EXT
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:36:47.449 [VENDOR SPECIFIC]
Error 30 [29] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 48 00 00 07 47 11 78 e0 00
Error: UNC 72 sectors at LBA = 0x07471178 = 122098040
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 48 00 00 07 47 11 78 e0 00 00:36:48.439 READ DMA EXT
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:36:47.449 [VENDOR SPECIFIC]
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:36:47.439 [VENDOR SPECIFIC]
25 00 00 00 48 00 00 07 47 11 78 e0 00 00:36:27.431 READ DMA EXT
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:36:26.443 [VENDOR SPECIFIC]
Error 29 [28] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 48 00 00 07 47 11 78 e0 00
Error: UNC 72 sectors at LBA = 0x07471178 = 122098040
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 48 00 00 07 47 11 78 e0 00 00:36:27.431 READ DMA EXT
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:36:26.443 [VENDOR SPECIFIC]
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:36:07.451 [VENDOR SPECIFIC]
25 00 00 00 48 00 00 07 47 11 78 e0 00 00:36:06.424 READ DMA EXT
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:36:05.436 [VENDOR SPECIFIC]
Error 28 [27] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 48 00 00 07 47 11 78 e0 00
Error: UNC 72 sectors at LBA = 0x07471178 = 122098040
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 48 00 00 07 47 11 78 e0 00 00:36:06.424 READ DMA EXT
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:36:05.436 [VENDOR SPECIFIC]
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:35:46.444 [VENDOR SPECIFIC]
25 00 00 00 48 00 00 07 47 11 78 e0 00 00:35:45.416 READ DMA EXT
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:35:45.344 [VENDOR SPECIFIC]
Error 27 [26] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 48 00 00 07 47 11 78 e0 00
Error: UNC 72 sectors at LBA = 0x07471178 = 122098040
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 48 00 00 07 47 11 78 e0 00 00:35:45.416 READ DMA EXT
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:35:45.344 [VENDOR SPECIFIC]
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:35:45.334 [VENDOR SPECIFIC]
25 00 00 00 08 00 00 07 47 11 78 e0 00 00:35:25.324 READ DMA EXT
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:35:25.240 [VENDOR SPECIFIC]
Error 26 [25] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 07 47 11 78 e0 00
Error: UNC 8 sectors at LBA = 0x07471178 = 122098040
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 08 00 00 07 47 11 78 e0 00 00:35:25.324 READ DMA EXT
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:35:25.240 [VENDOR SPECIFIC]
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:35:06.248 [VENDOR SPECIFIC]
25 00 00 00 80 00 00 07 47 11 40 e0 00 00:35:05.221 READ DMA EXT
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:35:05.140 [VENDOR SPECIFIC]
Error 25 [24] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 80 00 00 07 47 11 40 e0 00
Error: UNC 128 sectors at LBA = 0x07471140 = 122097984
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 80 00 00 07 47 11 40 e0 00 00:35:05.221 READ DMA EXT
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:35:05.140 [VENDOR SPECIFIC]
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:34:46.146 [VENDOR SPECIFIC]
25 00 00 00 08 00 00 07 47 11 78 e0 00 00:34:45.119 READ DMA EXT
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:34:45.039 [VENDOR SPECIFIC]
Error 24 [23] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 07 47 11 78 e0 00
Error: UNC 8 sectors at LBA = 0x07471178 = 122098040
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 08 00 00 07 47 11 78 e0 00 00:34:45.119 READ DMA EXT
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:34:45.039 [VENDOR SPECIFIC]
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:34:45.029 [VENDOR SPECIFIC]
25 00 00 00 80 00 00 07 47 11 40 e0 00 00:34:25.021 READ DMA EXT
ff 00 d5 00 01 00 00 00 00 00 01 00 ff 00:34:24.941 [VENDOR SPECIFIC]
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 677 -
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 0 --- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 4 9 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 10 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC